Home > Products > Diesel Generator > Brand New 80kw 1500rpm Diesel Generator Set with Cummins Engine

Brand New 80kw 1500rpm Diesel Generator Set with Cummins Engine

Basic Info

Model No.:  AC110-2

Product Description

Model NO.: AC110-2 Installation Method: Fixed Cooling Method: Water Cooling Speed: Speed Usage: Common Units Excitation Mode: AC Rotating Exciter Transport Package: Oam and PE Film Package, Plywood Package, Plastic Origin: China(Mainland) Type: Self-Starting Diesel Generator Stroke: Four Stroke Output Type: AC Three Phase Conditions of Use: Land Use Landuse Type of Unit: Low Noise Automation Type Trademark: Aosif Specification: 2085X785X1550 mm HS Code: 85021100  ♦ Assembled by Cummins diesel engine and famous brand Alternator.
♦ Radiator and fan with safety guard.
♦ Automatic control panel and 3 poles circuit breaker, internal cable.
♦ Battery charger and float battery charger as standard supply scope.
♦ Built-in anti-vibration pad
♦ High strength stand strong base.
♦ Optional voltage: 230V/400V, 220V/380V, 127V/220V, 240V/480V etc.
 
Genset Model AC110-II
Prime Power(50HZ) 80KW/100KVA
Standby Power(50HZ) 88KW/110KVA
Frequency/Speed 50Hz/1500rpm
Standard Voltage 230V/400V
effective voltage 220V/380V
Phases Three phases, four wires
Manufacturer AOSIF ENGINEERING LTD.
 
Manufacturer Dongfeng Cummins Engine Co., Ltd.
Model 6BT5.9-G2
Engine Speed 1500rpm
Engine Standby Power (LTP) -KW/BHP 92kw /123HP
Engine Prime Power (PRP) -KW/BHP 86kW/115HP
Type Four-stroke,Direct Injection,6 Cylinders
 
Aspiration Type Turbo charged
Bore mm/Stroke mm 102/120
Displacement 5.9 L
Idle -rpm 750-950
Piston speed -m/s 6.0
Friction power -KW 12.7

   
Load Fuel Consumption - g/kwh Fuel Consumption - L/h
Engine Output at generator set standby output 221 25
Engine Output at generator set prime output 214 22
Fuel Consumption at 75% of generator set prime output 216 17
Fuel Consumption at 50% of generator set prime output 217 11
Fuel Consumption at 25% of generator set prime output 248 6

      Exhaust System
Maximum allowable exhaust back pressure - kPa 10
Max. Exhaust Temperature(Before Turbo)-ºC 526
Exhaust Gas Flow - L/s 250
 
Intake System
 
Dirty filter air filter maximum inlet resistance -kPa 6
Standard type clean filter air filter maximum inlet resistance - kPa 4
 
Lubrication System
 
Normal operating oil pressure -kPa 345
Low idle speed -kPa 207
Rated speed-kPa 345
Allowable maximum oil temperature - ºC 121
Capacity of the oil pan (low - high) - L 12.3-14.2
Total system capacity-L 16.4
 
Fuel System
 
Fuel system form BYCA  type straight line pump
Maximum oil resistance - mmHg 102
Return oil resistance of the oil return line kPa 508
Total return flow - L/h 30
 
Cooling System
 
Cooling water capacity (engine, wet exhaust pipe) - L 7.9
Engine external maximum cooling water resistance- kPa 28
The maximum static pressure of cooling water above the center line of the engine crankshaft-m 14
Standard thermostat temperature adjustment range- ºC 82-95
Minimum pressure allowable pressure- kPa 69
Maximum box temperature--standby power/prime power- ºC 104/100
  Electrical System
 
Recommended minimum battery capacity -12ºCfor cold or above(400)
Maximum starting circuit resistance-Ω 0.002
Starting motor -V(volt) 24
Charging Alternator Capacity -A(ampere) 40
 
Model LSA44.3S5
Continuous/40- ºC 80kw
AVR Model R250
Number of phase 3
Power factor (Cos Phi) 0.8
Altitude  1000 m
Over speed 2250RPM
Number of Pole 4
Exciter type SHUNT
Insulation class H
Adjusting rate of stable voltage ±0.5%
Transient state voltage 300% (3 IN) : 10s
Wave aberration rate of votage( THD)  no load<2%,on load<5%
Telephone harmony wave factor of telephone TIF < 50
Telephone harmony wave factor of telephone TIF < 2%
Bearing Single
Coupling Direct
Protection class IP23
Balancing All rotors are strictly in accordance with ISO 1940 and NFC51-111 the standard requirements for balancing.
Generator technical parameters
Reactances (%). Time constants (ms) - Class H/400 V
Kcc Short-circuit ratio 0.54
Xd Direct-axis synchro. reactance unsaturated 287
Xq No-load transient time constant 172
T'do Direct-axis transient reactance saturated 2211
X'd Short-circuit transient time constant 12.9
T'd Direct-axis subtransient reactance saturated 100
X"d Subtransient time constant 7.7
T"d Quadrature-axis subtransient reactance saturated 10
X"q Zero sequence reactance unsaturated 16.1
Xo Negative sequence reactance saturated 0.39
X2 Armature 11.95
Ta No-load transient time constant 15
 
Other class H/400 V data
io No-load excitation current (SHUNT/AREP) 0.71/0.92
ic On-load excitation current (SHUNT/AREP) 2.24/2.89
uc On-load excitation voltage (SHUNT/AREP) 28.2/22.6
ms Response time (ΔU = 20% transient) 500
Kva(Shunt) Start (ΔU = 20% cont. or (ΔU = 30% trans.) SHUNT 295
Kva(AREP) Start (ΔU = 20% cont. or (ΔU = 30% trans.) AREP 354
% Transient ΔU (on-load 4/4) SHUNT - P.F.: 0.8 LAG 12.4
% Transient ΔU (on-load 4/4) AREP - P.F.: 0.8 LAG 9.7
W No-load losses 2317
W Heat dissipation 6789
 
Model(MCCB) CDM1-225/3300L-160A
Capacity(ACB) 160A
Capacity(ICU) 18KA TO 120KA
Voltage(Ue) 400V
 
Battery Voltage 12V
Battery Capacity 80Ah to 200Ah
Battery type Free maintenance, sealed lead-acid type
 
Open Type (Standard Configuration)
Overall Size: 2085*785*1550 mm(L*W*H)
Weight:1100 kg
 
Soundproof Version:
Overall Size: 2900*1160*1850 mm(L*W*H)
Weight : 1700kg

 

Contact us if you need more details on Generator. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Generator Set、Diesel Genset. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Diesel Generator