Find Diesel Generator, 58kVA Diesel Generator, Waterproof Diesel Generator on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Diesel Generator > Cheap Price Reliable Quality Power Generator Set

Cheap Price Reliable Quality Power Generator Set

Basic Info

Model No.:  AP10-II

Product Description

Model NO.: AP10-II Installation Method: Fixed Cooling Method: Water Cooling Speed: Speed Usage: Common Units Excitation Mode: AC Rotating Exciter Transport Package: Oam and PE Film Package, Plywood Package, Plastic Origin: China(Mainland) Type: Basic Diesel Generator Stroke: Four Stroke Output Type: AC Three Phase Conditions of Use: Land Use Landuse Type of Unit: Ordinary Trademark: Aosif Specification: 1088*500*1000 mm HS Code: 8502110000  Assembled by Perkins diesel engine and famous brand Alternator.
♦ Radiator and fan with safety guard.
♦ Automatic control panel and 3 poles circuit breaker, internal cable.
♦ Battery charger and float battery charger as standard supply scope.
♦ Built-in anti-vibration pad
♦ High strength stand strong base.
♦ Optional voltage: 230V/400V, 220V/380V, 127V/220V, 240V/480V etc.
Genset Model AP10-II
Prime Power(50HZ) 7KW/9KVA
Standby Power(50HZ) 8KW/10KVA
Frequency/Speed 50Hz/1500rpm
Standard Voltage 230V/400V
effective voltage 220V/380V
Phases Three phases, four wires
Manufacturer AOSIF ENGINEERING LTD.
 
Manufacturer Perkins Engines Company Limited
Model 403D-11G
Engine Speed 1500rpm
Engine Standby Power (LTP) -KW 8
Engine Prime Power (PRP) -KW 7
Type 4 stroke cycle , Non direct injection, 3 cylinder
 
Aspiration Type Naturally aspirated
 
Bore mm/Stroke mm 77/81
Displacement 1.131L
Compression Ratio 23:1
 
Load Fuel Consumption - -g/kWh Fuel Consumption - L/h
Engine Output at generator set Standby output 261 2.9
Engine Output at generator set prime output 252 2.6
Fuel Consumption at 75% of generator set prime output 258 2
Fuel Consumption at 50% of generator set prime output 286 2

      Exhaust System
 
Maximum allowable exhaust back pressure - kPa 10.2
Max. Exhaust Temperature(Before Turbo)-ºC 368
Exhaust Gas Flow - m³/min 1.66
 
 
Intake System
 
Dirty filter air filter maximum inlet resistance -kPa 6.4
Clean filter air filter maximum inlet resistance - kPa 3

Lubrication System
 
Minimum oil pressure - kPa 120
Safety valve opening pressure -kPa 304-500
Allowable maximum oil temperature - ºC 125
System total capacity -L 4.9
 
 
Fuel System
 
Fuel system form Perkins non direct injection system
Fuel pump pressure - kPa 10
Fuel pump maximum flow - L/h 63

Cooling System
 
Cooling water capacity - L 5.2
The maximum static pressure of cooling water above the center line of the engine crankshaft- kPa 30.4
Standard thermostat temperature adjustment range - ºC  75-87
Pressure cover pressure - kPa 90
Maximum box temperature--standby power/prime power- ºC 112

Electrical System
 
Recommended minimum battery capacity 80Ah
Starting motor -V(volt) 12 
Charging Alternator Capacity -A(ampere) 15/40
 
Model LSA40VS1
Continuous/40- ºC 8kw
AVR Model R220
Number of phase 3
Power factor (Cos Phi) 0.8
Altitude  1000 m
Over speed 2250RPM
Number of Pole 4
Exciter type SHUNT
Insulation class H
Adjusting rate of stable voltage ±0.5%
Transient state voltage 300% (3 IN) : 10s
Wave aberration rate of votage( THD)  no load<3%,on load<5%
Telephone harmony wave factor of telephone TIF < 50
Bearing Single
Coupling Direct
Protection class IP23
Balancing All rotors are strictly in accordance with ISO 1940 and NFC51-111 the standard requirements for balancing.

Generator technical parameters
Reactances (%). Time constants (ms) - Class H/400 V
Kcc Short-circuit ratio 0.72
Xd Direct-axis synchro. reactance unsaturated 167
Xq No-load transient time constant 100
T'do Direct-axis transient reactance saturated 780
X'd Short-circuit transient time constant 17.2
T'd Direct-axis subtransient reactance saturated 74
X"d Subtransient time constant 8.6
T"d Quadrature-axis subtransient reactance saturated 7
X"q Zero sequence reactance unsaturated 16.1
Xo Negative sequence reactance saturated 0.1
X2 Armature 12.4
Ta No-load transient time constant 11

Other class H/400 V data
io No-load excitation current (SHUNT/AREP) 0.8/1.1
ic On-load excitation current (SHUNT/AREP) 2/2.7
uc On-load excitation voltage (SHUNT/AREP) 25/18
ms Response time (ΔU = 20% transient) <300
Kva(Shunt) Start (ΔU = 20% cont. or (ΔU = 30% trans.) SHUNT 25
Kva(AREP) Start (ΔU = 20% cont. or (ΔU = 30% trans.) AREP 25
% Transient ΔU (on-load 4/4) SHUNT - P.F.: 0.8 LAG <16%
% Transient ΔU (on-load 4/4) AREP - P.F.: 0.8 LAG <16%
W No-load losses 460
W Heat dissipation 1610
 
Model(MCCB) CDM1-100L/3300-63A
Capacity(ACB) 63A
Capacity(ICU) 18KA TO 120KA
Voltage(Ue) 400V
 
Open Type (Standard Configuration)
Overall Size: 1088*500*1000 mm(L*W*H)
Weight:353 kg
 
Soundproof Version:
Overall Size: 1950*1060*1370 mm(L*W*H)
Weight : 783kg
 
 
 

Contact us if you need more details on Power Supply. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Perkins Generator、Perkins Generator Set. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Diesel Generator

Email to this supplier
  • *Subject: